Procedures

ESPORG Sustainable Parking Management Standard (SPMS)
Effective date: 21 October 2026

1. Purpose

These Procedures govern approval of Certification Bodies, auditor qualification, certification, recertification, surveillance, certificate status, complaints and appeals under the SPMS Charter.

2. Certification Bodies and auditors

Only Certification Bodies approved by ESPORG for SPMS may conduct SPMS audits and issue SPMS certificates.

A Certification Body shall demonstrate:

  • legal identity, financial stability and appropriate insurance;
  • competence, impartiality and operational capacity;
  • separation between audit activity and certification decisions;
  • qualified auditors with a formal contractual relationship to the Certification Body; and
  • conformity with ISO/IEC 17065 or an equivalent accepted conformity-assessment framework, including a credible pathway to accreditation where necessary.

 

Auditors shall be trained and competent for the current SPMS Charter, these Procedures, the certification criteria, audit methodology and professional ethics. They shall have working knowledge of English and sufficient knowledge of the relevant local language.

A Certification Body, auditor or certification decision-maker shall not audit or certify a facility where it has provided consultancy, prepared the evidence package, supplied assessed equipment or has another material conflict of interest.

Applications for Certification Body approval shall be submitted to the Secretariat. The Secretariat carries out an administrative review. The Advisory Board evaluates competence, independence, procedures and conflicts of interest and makes a recommendation to ESPORG. ESPORG publishes the approved Certification Bodies and their scope.

3. Application

An operator shall apply directly to an approved Certification Body.

The application shall include:

  • operator and facility identity;
  • site boundary and requested certification scope;
  • self-assessment against the current criteria;
  • evidence for claimed criteria;
  • relevant legal-baseline information; and
  • declaration of material changes and prior relevant suspensions or withdrawals.

 

The Certification Body shall confirm eligibility, scope, competence and impartiality before accepting the application.

4. Audit and certification

Initial certification and recertification require a document review and on-site audit. Every 12 months the Certification Body will conduct a simplified surveillance check as to the compliance with the certification criteria (remote or onsite).

The audit shall verify the facility, scope, evidence, applicable legal baseline, claimed criteria, operating records and public SPMS claims.

The Certification Body shall issue a written audit result without undue delay. Certification decisions shall be made independently from the audit team.

Findings are classified as follows:

  • Minor non-conformity: a limited failure not affecting the certified level; a correction plan is required.
  • Major non-conformity: a significant failure affecting conformity or score; certification shall not be granted or maintained until corrected.
  • Critical non-conformity: fraud, serious misleading claim, absence of a mandatory condition, material conflict of interest or a failure affecting the certified level; certification shall not be granted or maintained.

The Certification Body shall describe non-conformities in writing and set a proportionate correction deadline. The operator shall provide evidence of corrective action. A future commitment alone is not evidence of conformity.

The Certification Body shall review corrective action within four weeks of receiving sufficient evidence, unless a site visit or other justified assessment requires more time.

Where the verified result corresponds to a different level, scope or score, the Certification Body shall issue a revised certificate or refuse certification, as applicable.

5. Certificates and recertification

A certificate is valid for a maximum of three years, subject to surveillance and continued conformity.

The certificate shall show the certificate number, facility, operator, scope, exclusions, Standard version, level and score where applicable, Certification Body, issue date, expiry date and verification link or QR code.

The operator shall request recertification at least three months before expiry. The recertification audit should be completed before expiry.

In exceptional, documented circumstances, the Certification Body may extend a certificate once for up to six months. The extension shall be justified in writing, notified to the Secretariat and shown in the public register.

6. Surveillance and material change

The Certification Body shall conduct at least one surveillance activity in each 12-month period of validity. Surveillance may include document review, remote verification, site visit, data review or claims monitoring.

The operator shall notify the Secretariat and Certification Body within 30 days of a material change that may affect certification. This includes a change of operator, site boundary, certified feature, energy arrangement, service, evidence or public claim.

The Certification Body may require a desk review, special audit, correction, scope amendment, level reduction, suspension or withdrawal.

The Advisory Board may request a special audit or review where there is a complaint, inconsistent evidence, material change, repeated non-conformity, misleading claim or other material integrity risk.

7. Suspension and withdrawal

A certificate may be suspended or withdrawn where the facility no longer conforms, a material change is not reported, surveillance is refused, evidence is false or incomplete, a prohibited claim is used, or corrective action is not completed in time.

The Certification Body shall notify the operator and Secretariat in writing. The Secretariat shall update the public register promptly.

During suspension or after withdrawal, the operator shall stop presenting certification as current and remove the SPMS name, mark and related claims from physical and digital material within 10 business days, unless a shorter period is required to avoid misleading users.

8. Public information

After certification, recertification, suspension, withdrawal or expiry, the Certification Body shall notify the Secretariat without undue delay.

The Secretariat shall maintain a free public register showing the facility, operator, certificate number, scope, level, Standard version, Certification Body, issue date, expiry date and current status, together with a verification link or QR code.

9. Claims clearance

Routine use of the approved SPMS mark and standard public description does not require individual clearance.

The Secretariat checks completeness and refers the claim to the Advisory Board. The Advisory Board may clear, require amendment, restrict or reject the claim. Clearance does not remove the operator’s legal responsibility for its communications.

10. Complaints and appeals

Any person may submit a complaint concerning a facility, Certification Body, audit, certificate, SPMS claim, mark use, governance matter or procedure.

The Secretariat records and acknowledges complaints within 10 business days. The Advisory Board determines the competent route and ensures an independent, documented response or progress update, normally within 60 days.

An applicant or operator may appeal a certification decision, scope, level, suspension or withdrawal within 30 days of notification.

Appeals shall be decided by the Advisory Board. The Advisory Board shall issue a reasoned decision normally within 90 days.

11. Records and confidentiality

Operators and Certification Bodies shall retain relevant certification records for at least six years after expiry or withdrawal. ESPORG shall retain public-register, complaint and appeal records for the same period.

Personal data and confidential business information shall be handled in accordance with applicable law. Confidentiality does not prevent publication of certificate status, scope or other information necessary to avoid misleading users.